| IEC60092 Offshore & Marine Cables | |||
| MariTox Marine Flame Retardant Medium Voltage Cables | MariTox Marine Flame Retardant Power & Control Cables | MariFlex Marine Fire Resistant Power & Control Cables | other |
Power Distribution Cables
300V Twisted pairs unshielded Type T signal cables
Construction
Conductor:
Stranded copper conductor tin or alloy coated where necessary for the application , conductor per ASTM or IEC
60228.
Separator tape: optional
Insulation:
Polyvinylchloride(PVC) according to IEEE 1580 2010 Type T,Type X, E, T/N, S, P, LSX and LSE as option.
Pairs:
Jacket:
Thermosetting Polychloroprene(neoprene) according to IEEE 1580 2010 Type N,
Type T, CP, CPE, L, P or TPO jacket as option (optional for Type P with HD thicknesses).
Armor: optional and shall be nonmagnetic
Sheath:
Thermosetting Polychloroprene(neoprene) according to IEEE 1580 2010 Type N,
Type T, CP, CPE, L, P or TPO sheath as option (optional except for tinned copper braid armoured cables).
Optional:
For halogen-free constructions, Type LSX, LSE or LSS insulation shall be used with a Type L or TPO
jacket/sheath.
Table B.11—Typical dimensions and weights; twisted-pair signal cable 300 V; Type T unshielded pairs
Number of conductors |
Conductor |
Unarmored | Armored | Armored and sheathed | |||
|---|---|---|---|---|---|---|---|
| Nom. dia. (in) | Approx. weight (lb/1000 ft) | Nom. dia. (in) | Approx. weight (lb/1000 ft) | Nom. dia. (in) | Approx. weight (lb/1000 ft) | ||
| 1 | 20 | 0.28 | 35 | 0.34 | 51 | 0.44 | 88 |
| 2 | 20 | 0.39 | 58 | 0.45 | 79 | 0.57 | 139 |
| 3 | 20 | 0.44 | 76 | 0.5 | 100 | 0.62 | 165 |
| 4 | 20 | 0.48 | 92 | 0.54 | 119 | 0.66 | 189 |
| 5 | 20 | 0.56 | 127 | 0.62 | 158 | 0.75 | 241 |
| 6 | 20 | 0.58 | 142 | 0.64 | 173 | 0.77 | 260 |
| 8 | 20 | 0.64 | 174 | 0.7 | 207 | 0.82 | 298 |
| 10 | 20 | 0.72 | 210 | 0.78 | 247 | 0.95 | 391 |
| 15 | 20 | 0.8 | 283 | 0.86 | 323 | 1.03 | 480 |
| 20 | 20 | 0.91 | 392 | 0.97 | 439 | 1.14 | 610 |
| 25 | 20 | 1.04 | 477 | 1.1 | 530 | 1.27 | 726 |
| 30 | 20 | 1.09 | 550 | 1.15 | 606 | 1.32 | 806 |
| 40 | 20 | 1.22 | 698 | 1.28 | 763 | 1.45 | 989 |
| 50 | 20 | 1.34 | 845 | 1.4 | 916 | 1.56 | 1151 |
| 60 | 20 | 1.52 | 1002 | 1.58 | 1082 | 1.81 | 1465 |
| 1 | 18 | 0.3 | 43 | 0.36 | 59 | 0.46 | 98 |
| 2 | 18 | 0.42 | 74 | 0.48 | 98 | 0.61 | 166 |
| 3 | 18 | 0.48 | 98 | 0.54 | 125 | 0.66 | 196 |
| 4 | 18 | 0.55 | 138 | 0.61 | 167 | 0.74 | 250 |
| 5 | 18 | 0.61 | 165 | 0.67 | 198 | 0.8 | 289 |
| 6 | 18 | 0.63 | 186 | 0.69 | 219 | 0.82 | 312 |
| 8 | 18 | 0.69 | 232 | 0.75 | 267 | 0.92 | 402 |
| 10 | 18 | 0.78 | 281 | 0.84 | 321 | 1.01 | 471 |
| 15 | 18 | 0.91 | 424 | 0.97 | 471 | 1.14 | 640 |
| 20 | 18 | 0.99 | 533 | 1.05 | 583 | 1.22 | 765 |
| 25 | 18 | 1.13 | 652 | 1.19 | 708 | 1.36 | 912 |
| 30 | 18 | 1.19 | 758 | 1.25 | 820 | 1.42 | 1034 |
| 40 | 18 | 1.33 | 972 | 1.39 | 1043 | 1.56 | 1279 |
| 50 | 18 | 1.46 | 1185 | 1.52 | 1263 | 1.76 | 1637 |
| 60 | 18 | 1.66 | 1409 | 1.72 | 1498 | 1.96 | 1917 |
| 1 | 16 | 0.32 | 51 | 0.38 | 69 | 0.48 | 110 |
| 2 | 16 | 0.45 | 90 | 0.51 | 114 | 0.64 | 185 |
| 3 | 16 | 0.51 | 121 | 0.57 | 150 | 0.7 | 227 |
| 4 | 16 | 0.59 | 169 | 0.65 | 200 | 0.78 | 287 |
| 5 | 16 | 0.66 | 202 | 0.72 | 237 | 0.89 | 369 |
| 6 | 16 | 0.68 | 231 | 0.74 | 266 | 0.91 | 400 |
| 8 | 16 | 0.75 | 290 | 0.81 | 327 | 0.98 | 475 |
| 10 | 16 | 0.89 | 388 | 0.95 | 433 | 1.12 | 604 |
| 15 | 16 | 0.99 | 532 | 1.05 | 582 | 1.22 | 770 |
| 25 | 16 | 1.23 | 827 | 1.29 | 892 | 1.46 | 1117 |
| 30 | 16 | 1.3 | 966 | 1.36 | 1034 | 1.52 | 1261 |
| 40 | 16 | 1.45 | 1246 | 1.51 | 1322 | 1.74 | 1682 |
| 50 | 16 | 1.59 | 1524 | 1.65 | 1607 | 1.88 | 1994 |
| 60 | 16 | 1.88 | 1928 | 1.94 | 2028 | 2.17 | 2491 |
NOTE—These values are for reference purposes only and should not be construed as requirements. Dimensions are based on the use of Class B conductors. Weights of armored constructions are based on aluminum braid armor. It is recommended that the user/specifier contact the manuf acturer for manufacturer specific values.
The parameters listed above are nominal values as per cable standards. Actual values may vary due to material and manufacturing process variations. For precise specifications or customized requirements, please contact us for further information